Mobile Dehumidifier CDT 22 / 35 / 50 / 85 INSTRUCTIONS

Electronic Control:

The entire control of this mobile unit, inclusive of safety, control and ON/OFF functions is taken care of by the CDG 2 circuit board. The light diodes on the control panel give the following indications:

 

  1. The drier unit is on with the compressor is running
  2. The temperature/pressure on the condenser side is too high. The unit is switched off for 44 minutes before automatic restart. The LED is on and indicates a failure
  3. The temperature in the room is too low. At temperatures under 3c the unit stops. If the ambient temperature increases to more than 3c, the unit starts again automatically
  4. The mobile unit is switched off because the water container is full
  5. The unit is in defrosting mode. During defrosting the compressor is working and the fan is stopped
  6. The evaporator is icing up

Fault Finding:

NOTE: Wait one minute before starting to locate the fault, as the electronic control may have switched off the unit for safety reasons

The dehumidifier does not start, the green lamp does not light up.
Check the power supply to the unit and the cable is plugged into a socket. If so, check the fuses to the plug or an extension lead..

The dehumidifier does not start, but the green lamp is on. The hygrostat is probably set too high. Reduce its setting. If the unit does not start, remove the hygrostat. If the unit starts to work now the hygrostat is defective.

Signals from the LED’s on the electronic control.

  1. Pressure and temperature on the high pressure side of the cooling plant is too high. Check filter and unit for dirt. Check that the fan is working
  2. Room temperature below 3c, wait until the room temperature is above 3c
  3. The water container is full. Empty the water container

If the mobile drier does not start again contact London Cool on 0800 440 444. This also applies if the unit is running but not producing any water. This is probably due to a fault in the cooling circuit, which can only be repaired by a refrigeration engineer.

NOTE – IF THE UNIT DOES NOT WORK IT SHOULD BE SWITCHED OFF IMMEDIATLEY

Technical Specifications:

Model

CDT 22

CDT 35

CDT 50

CDT 85

Working range humidity

%RH

40-100

40-100

40-100

40-100

Working range temperature

C

3-30

3-30

3-30

3-30

Power supply

V/Hz

230/50

230/50

230/50

230/50

Max current consumption

A

2,9

2,7

4,1

6,9

Max power consumption

W

600

700

950

1500

Air volume

m3/h

280

400

800

1000

Refrigerant

-

R 407 C

R 407 C

R 407 C

R 407 C

Refrigerant quantity

g

300

475

575

1600

Capacity of water container

I

5,5

12,5

12,5

-

Sound level 1m distance

DB(A)

57

59

61

64

Weight

kg

41

52

60

74

London Cool portable air conditioner rental & sales, driers and heaters

This document has been compiled in good faith, but no representation is made or warranty given (either express or implied) as to the completeness or accuracy of this information

 

Fans and Air Movers Water Chiller Rental Fixed Air Conditioning 
Evaporative Coolers Portable Air Conditioners - Small Office Portable Air Conditioners - Open Plan Office 
Portable Air Conditioners - Server/computer/Data Rooms Portable Air Conditioners - Industrial Electronic Air Purification 
Humidifiers Dehumidifiers Event Heating and Cooling 
Heaters 

Surveys and Designs Air Conditioning Installation Air Conditioning Servicing


spacer spacer
spacer